MCS Test Equipment, Providing State of the Art Technology

We are one of the leading suppliers of test equipment and support services to the wireless communications industry.

08453 626365 - sales@mcs-testequipment.co.uk

Clare A203ES Analogue Hipot/Flash/Dielectric Withstand Tester Covering Voltages from 0 to 5kV AC

Clare A203ES Analogue Hipot/Flash/Dielectric Withstand Tester Covering Voltages from 0 to 5kV AC

The A203ES hipot tester is a cost effective, simple to use, rugged test system suited to manufacturing or laboratory environments. It can deliver a test voltage of 0 to 5 kV a.c. from an internal 500VA transformer source, and has displays that show both output voltage and current flow. Over-current or flash/dielectric breakdown are indicated by a latching lamp and audible lamp, with separate fault reset button. This product comes with the trademark Clare sprung shrouded safety probes. This product is suited to conformance type test laboratories as it meets the requirements of EN 60335-1 and other international standards that require a leakage capability in excess of 100mA.

 

The A203 range of hipot testers is robust and simple to use. Each instrument is ideally suited to manufacturing or laboratory environments and offers high accuracy control, allowing continuous selection of voltage from 0 to 15kV AC from a 500VA transformer source. Output voltage is clearly displayed on moving analogue meters. Also available is a selection of features which includes current monitoring from variable trip settings for over-current and audio-visual indication. All A203 instruments are supplied with probes and are ideal for testing to a variety of international safety standards.

Key Features:

  • Cost Effective electrical safety testing
  • Simple to use hipot tester
  • Clear, easy to read, panel meters
  • Rugged design
  • Versatile
  • Test probes supplied
  • Special flash test set for laboratory type tests such as EN 60335-1 etc
  • Adjustable voltage, 0-5kV a.c. from a 500VA transformer source.
  • Twin analogue meter displays
  • Applied voltage - scaled 0-5kV a.c.
  • Total Leakage - scaled 0-5mA (read as x10 & x100 with higher trip levels selected).
  • Key switch selectable trip levels of 5, 25 or 125 mA.
  • Over current or Flash breakdown indicated by maintained lamp and audible alarm.
  • Fault indication reset by safety button.
  • Push button trip by-pass (burn-out) facility for fault tracing.
  • Complete with pair of sprung shrouded safety test probes.

 

Technical Specification

  • HIPOT TEST OUTPUT VOLTAGE
    • Variable from 0-5 kV a.c
  • HIPOT TEST CURRENT TRIP RANGE
    • 5, 25 or 125mA key selectable but can be bypassed up for burn-out facility
  • DIMENSIONS
    • 450L x 255H x 300D (mm)
  • WEIGHT
    • 25 kg
  • SUPPLY VOLTAGE
    • 120V or 230V
    • 50 or 60 Hz

Product Categories: High Voltage Test

  • Model Number: A203ES
  • Categories: High Voltage Test
  • Manufacturer: Clare
  • Pricing: We have special and exclusive offers that change constantly. Please request a quote so we can get you the best price.
  • Delivery: Free and quick delivery

There are currently no attachments for this product. If you require further information please contact us